Please login to the repository to save this object to your list.
Cite this document
Brajković, M., Barac, M., Cosic, D. D., Bogdanović Radović, I. & Siketić, Z. (2021). Development of MeV TOF-SIMS capillary microprobe at the Ruder Boskovic Institute in Zagreb [Data set]. doi:10.5281/zenodo.5970477
Brajković, Marko, et al. Development of MeV TOF-SIMS capillary microprobe at the Ruder Boskovic Institute in Zagreb. Institut Ruđer Bošković, 2021. 17 Nov 2024. doi:10.5281/zenodo.5970477
Brajković, Marko, Marko Barac, Domagoj Donny Cosic, Ivančica Bogdanović Radović, and Zdravko Siketić. 2021. Development of MeV TOF-SIMS capillary microprobe at the Ruder Boskovic Institute in Zagreb. Institut Ruđer Bošković. doi:10.5281/zenodo.5970477
Brajković, M., et al. 2021. Development of MeV TOF-SIMS capillary microprobe at the Ruder Boskovic Institute in Zagreb. Institut Ruđer Bošković. [Online]. [Accessed 17 November 2024]. Available from: https://doi.org/10.5281/zenodo.5970477
Brajković M, Barac M, Cosic DD, Bogdanović Radović I, Siketić Z. Development of MeV TOF-SIMS capillary microprobe at the Ruder Boskovic Institute in Zagreb. [Internet]. Institut Ruđer Bošković: Zagreb, Bijenička 54, HR; 2021, [cited 2024 November 17] Available from: https://doi.org/10.5281/zenodo.5970477
M. Brajković, M. Barac, D. D. Cosic, I. Bogdanović Radović and Z. Siketić, Development of MeV TOF-SIMS capillary microprobe at the Ruder Boskovic Institute in Zagreb, Institut Ruđer Bošković, 2021. Accessed on: Nov 17, 2024. Available: https://doi.org/10.5281/zenodo.5970477
Zdravko Siketić Institut Ruđer Bošković Ruđer Bošković Institute
Scientific / art field, discipline and subdiscipline
NATURAL SCIENCES Physics Nuclear Physics
Abstract (english)
New Time-of-flight Secondary Ion Mass Spectrometry (TOF SIMS) setup using MeV heavy ions for the excitation is developed at the Ruđer Bošković Institute accelerator facility. To focus heavy MeV ions to micron dimensions,
conical glass capillary is used instead of quadrupole magnetic lenses. The setup uses a continuous primary beam where the START signal for TOF is obtained from the PIN diode placed behind the thin transmission sample. Measured energy spectra for several primary heavy ions are presented and compared with theoretical simulations. The first mass spectra obtained with the new setup using reflectron-type TOF analyzer are given together with the mass and spatial resolution values of the new setup.
Number: IP-2016-06-1698 Title (croatian): Razvoj kapilarne mikroprobe za MeV SIMS s primjenom na analizu bioloških materijala Acronym: BioCapSIMS Leader: Ivančica Bogdanović Radović Jurisdiction: Croatia Funding stream: IP
Project
Number: 824096 Title (croatian): Research And Development with Ion Beams – Advancing Technology in Europe-RADIATE